← All tools

Room Lux Calculator

Tell it the room size and what the space is for, and it works out how many fixtures you need, how many lumens that is, and what it costs you in watts. Free, no sign up.

Your room

200 lux

You need about

11

fixtures of Downlight 12W

That lands you at roughly 206 lux, against a 200 lux target.

Floor area

26 m²

Suggested layout

4 × 3

Spacing

5 ft × 4.7 ft

Total load

132 W

What this means

Your room is 26 square metres and needs about 13,200 lumens in total to reach 200 lux. Spread over 11 fixtures that is 1,200 lumens each, drawing 132 watts altogether, or 5.1 watts per square metre.

An estimate, not a lighting design. It assumes an even ceiling grid, mid range wall and ceiling colours, and a working plane 0.8m off the floor. Dark walls, odd shapes, high racking or a narrow beam angle will all pull the real figure around.

Lumens, watts and lux, in plain terms

Lumens

how much light comes out

The total light a fitting produces. This is the number to compare when you are shopping. It is printed on the box, usually next to the wattage.

Watts

how much electricity goes in

What it costs to run, not how bright it is. LED broke the old habit of judging brightness by wattage. A 9W LED can match an old 60W bulb.

Lux

how much light lands on the surface

Lumens spread over an area. One lumen falling on one square metre is one lux. It is what you actually experience in the room, and it drops as the room gets bigger or the ceiling gets higher.

The one that trips people up

Two fittings both marked 18W can differ by a third in actual output, because one runs at 70 lumens per watt and the other at 110. If you buy by watts you are guessing. Ask for the lumens, then divide by the watts to see how efficient it really is. Anything near 100 lumens per watt is respectable for LED today.

How many downlights does a room need?

A starting point for a typical Malaysian home, using 12W LED downlights of about 1,100 lumens each on a 2.8m ceiling with light coloured walls. Use the calculator above for your own room, since ceiling height and wall colour move these numbers.

Room sizeFloor areaBedroomLiving roomKitchen or office
2.5m x 3m8 m²235
3m x 3m9 m²236
3m x 4m12 m²347
3.5m x 4m14 m²459
4m x 4m16 m²4610
4m x 5m20 m²5712
4m x 6m24 m²6915
5m x 6m30 m²81119
5m x 8m40 m²101425

Read the kitchen column with care

Those counts assume the downlights are doing all the work. Most kitchens do not work that way. Put strip lighting under the wall cabinets to light the worktop and you can drop the ceiling count by a third, and the result is better, because the light lands where you are actually cutting instead of behind your shoulder. The same applies to an office with desk lamps.

How much lux does each space need?

The usual ranges, following Malaysian Standard MS 1525 and the international EN 12464-1. Guidance for a home, and what a consultant or inspector will expect in a workplace.

SpaceTarget luxNotes
Bedroom100 to 150Warm white, and worth putting on a dimmer
Living room150 to 200Lift it with lamps rather than more ceiling lights
Dining150 to 200Plus a pendant over the table
Kitchen300500 on the worktop, which is what under cabinet strip is for
Bathroom150 to 200300 at the mirror, and IP rated near the shower
Study or home office300 to 500500 only where the work happens
Corridor or stairs100 to 150Even coverage matters more than brightness
Retail floor500Higher again on feature displays
General factory work300Usually high bay at this ceiling height
Warehouse storage150Aisle coverage, not floor average

LED watts against the old bulb you are replacing

If you know the old bulb was 60W and you want the same brightness, this is the row you want. Match on lumens, and treat the LED wattage as a guide, since efficiency varies between fittings.

Old incandescentLumensLED equivalent
25W250 lm3W
40W450 lm5W
60W800 lm9W
75W1,100 lm12W
100W1,600 lm17W
150W2,600 lm28W
36W fluorescent tube, 4ft1,800 lm18W T8 LED

The LED column assumes roughly 95 lumens per watt. A cheap fitting at 70 needs more watts for the same light, and a good one at 130 needs fewer, which is the whole reason to shop by lumens.

How the numbers are worked out

This uses the lumen method, the same approach used for a proper lighting layout.

fixtures = (target lux × floor area) ÷ (lumens per fixture × UF × MF)

UF, the utilisation factor. Not all the light reaches the floor. Some is absorbed by the walls and ceiling. Tall narrow rooms lose more than wide low ones, so the calculator works this out from your room shape and ceiling height rather than asking you for it.

MF, the maintenance factor. Dust settles on fittings and LED output fades slowly over the years. Designing to exactly the target means being under it within a year or two, so we allow for it up front. 0.8 is the normal assumption indoors, lower in a dusty workshop.

Recommended lux levels here follow the usual ranges in Malaysian Standard MS 1525 and the international EN 12464-1. They are guidance rather than law for a home, but for offices and workplaces they are what an inspector or a consultant will expect.

Common questions

How many lumens do I need per square metre?

Multiply your target lux by the floor area, then add back what the room loses. A 20 square metre living room at 200 lux needs 4,000 lumens landing on the floor, but you have to supply more than that because light is absorbed by walls and lost over time. In practice that room usually needs somewhere around 8,000 to 10,000 lumens of fittings. The calculator does that step for you.

What is the difference between lumens and watts?

Lumens measure the light coming out. Watts measure the electricity going in. In the incandescent days the two moved together, so people learned to shop by watts, and a 60W bulb meant a known brightness. LED broke that link. A 9W LED can produce the same light as an old 60W bulb. When you compare fittings, compare lumens. Watts only tell you what it costs to run.

What is a good lumens per watt figure for LED?

Around 100 lumens per watt is normal for a decent LED fitting today. Cheap ones sit at 70 or lower, and good ones reach 130 and above. Two fittings both marked 18W can differ by a third in actual light output, which is why buying by watts alone leaves you guessing.

How many lux should a room have in Malaysia?

As a rough guide, a living room sits around 150 to 200 lux, bedrooms about 100 to 150, kitchens 300 with 500 over the worktop, a study or home office 300 to 500, retail floors 500, general factory work 300, and warehouse storage around 150. Malaysian Standard MS 1525 and the international EN 12464-1 both set out recommended levels by task if you need something more precise.

Why does the calculator ask for ceiling height?

Because height changes how much of the light actually reaches the floor. A high ceiling spreads light over a wider area and loses more of it to the walls before it gets down to you, so the same fitting delivers less lux at the working plane. It also affects spacing, since fittings mounted high need to be further apart to avoid overlapping into hot spots.

Is this good enough to buy from?

It is good enough to plan with and to sanity check a quotation. It assumes an even ceiling grid, mid range wall colours and a clear room. Dark walls, tall racking, odd room shapes and narrow beam angles all shift the answer. For anything you are committing money to, send us the room and we will go through it with you.

Want a second opinion on the numbers?

Send us the room and what it is for. We will tell you honestly if the calculator is close, and what we would actually put in.